Mitigating Corrosion Under Insulation (CUI)

Corrosion Under Insulation (CUI) is a persistent challenge in industrial settings, primarily because it tends to remain undetected until significant damage has occurred. Once moisture or other chemical agents penetrate an insulation system, corrosion begins and continues unchecked unless proper preventative measures are in place. To mitigate the risk of CUI in pressure vessels and storage tanks, it is crucial to address insulation at the design stage and ensure proper installation techniques.

Understanding How Water Penetrates Insulation

The presence of water is essential for corrosion to occur. If moisture is effectively prevented from entering the insulation system, CUI can be avoided altogether. Water can infiltrate an insulation system in three primary ways:

  • Gaps or openings in cladding: These allow direct ingress of rain, spills, or other liquids, leading to localized corrosion.

  • Water vapor infiltration: Gaps in cladding can enable air movement, allowing water vapor to enter the insulation system. This is particularly problematic in systems with fluctuating temperatures.

  • Water vapor diffusion: Moisture can slowly penetrate insulation material through vapor diffusion, a common issue in systems exposed to humidity.

Design Considerations for CUI Prevention

Effective mitigation of CUI starts at the mechanical design stage. Insulation should never be an afterthought, as improper planning can compromise the integrity of the entire system. Key considerations include:

  • Surface protection philosophy: The materials used in plant equipment, pipework, and vessels should be selected with CUI prevention in mind, ensuring they are suited for their environmental conditions.

  • Proper pipe supports and sealing: Cladding and insulation must be continuous and well-sealed at pipe supports to prevent gaps that allow moisture ingress.

  • Avoidance of upward-facing penetrations: These are nearly impossible to seal effectively for the entire lifetime of a plant, making them a high-risk area for water entry.

  • Incorporation of insulation and cladding fixing points during equipment fabrication: Properly designed fixing points ensure that insulation remains intact and securely fastened, reducing vulnerabilities.

  • Adequate sizing of pipe stubs and manways: These must be long enough to accommodate the full insulation thickness while allowing proper termination of cladding.

  • High-quality specifications: Awareness of insulation thickness requirements is essential to allow sufficient space for proper installation without compromising other equipment.

  • Service temperature, climate, and location considerations: The chosen insulation system must be suited for the environmental conditions it will face, ensuring long-term protection.

The Role of Temperature Fluctuations

One overlooked factor in CUI prevention is the fluctuation of operating temperatures. While hot insulation systems generally repel moisture due to high temperatures, they can still become vulnerable when off-load. If the temperature inside the insulation falls below ambient conditions, condensation can form, increasing the risk of CUI. This is especially relevant in environments with high humidity or frequent shutdown periods.

Conclusion

Preventing CUI requires a proactive approach at the design, installation, and maintenance stages. Ensuring a well-sealed insulation system, selecting appropriate materials, and incorporating proper design features can significantly reduce the risk of corrosion. By prioritizing these considerations from the beginning, industries can enhance the longevity and reliability of their pressure vessels and storage tanks while minimizing costly repairs and downtime.